It doesnt mean it is ready to go at 230. I opened the back and everything looks fine, Hi Matthew, the pump capacitor is the first suspect, it may be weak and needs replacement. The electrician also installed w new capacitors on the pump and still same problem. Free, Pool Equipment Parts: Make your Own Repairs, https://www.intheswim.com/p/hayward-super-pump-pool-pump-motor-1-5-hp-threaded-shaft, https://www.intheswim.com/p/hayward-super-pump-shaft-seal-assembly-spx1600z2, http://waterheatertimer.org/How-to-wire-Hayward-two-speed-pump.html, https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/super-pump-vs-S2603VSP.pdf?fromCDN=true, https://www.intheswim.com/c/filter-parts?pcode=208&scode=SOCIBLOG, https://www.totallyhayward.com/techservices/attachments/Serial%20Number%20Read%20REVISED%201-2012.pdf, https://www.intheswim.com/images/PDFs/E1964-Manual.pdf, https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/tristar-vs-S3202VSP.pdf?fromCDN=true, https://www.intheswim.com/c/pump-parts?pcode=208&scode=SOCIBLOG, https://www.intheswim.com/p/hayward-spring-seal-w-seat-spx1250xz2c. Hi probably not related to the vacuuming, but sounds like a motor problem. Turned it off tho clear the skimmer basket.. water level is correct. After doing some reading, I now understand that the IG pump shouldnt be used with the AG pool and weve been doing the wrong thing for almost 30 years. And 93, thats just the temp of the water, the flames are much hotter of course, thats what is melting the plastic. But not a dirty filter? I have a pump that wants to stop pumping water after a few minutes the flow gets very low. Why is this happening? The breaker on the panel tripped. If you find out, I would check the owners manual for information related to your symptoms. Fix this problem simply by tightening or adjusting the wires and connections in the motor. To spin the shaft, to find out of it spins freely, open up the rear of the pump motor, with power off, and use your fingers to spin the shaft. All Rights Reserved. Third, is there a valve closed after the filter, or some other obstruction? If the switch does not close after the blower starts the control will go into lockout with the blower running. Now it runs nice and quiet but still overheats and shuts off. What am I missing? The post-purge cycle will be completed once the blower prover switch closes. Just bought a hayward super II pump. Replacing it involves separating the wet end from the motor end, then holding the shaft so you can unthread the impeller, removing the two old seal halves, and replacing in the same direction or orientation to each other, rethreading on the impeller and reconnecting the seal plate to the pump housing. Hi, I have a hayword C48L2N134B3 1.5 HP pool pump. I shut the pump down the other night and it will not run. What should I do? My Hayward mother is a 1.5 hp. See below for more detail. Scrape out the old gasket with a sharp screwdriver and glue a new one in place with dabs of superglue gasket flat side down, ridged side up. I have a Hayward super pump every once in awhile when I go to unplug to backwash it sparks and trips the breaker. It looks like I need to change out the pump. I can see the water trickling in to the filter after a while, and the output becomes very limited. This is more of an indicator light than anything else. Can I turn on this pump without water to check whether the motor is running? Good luck! If you have a filter pressure gauge, the practice is to clean the filter when the pressure gauge rises 7-9 psi above the clean, starting pressure. "mainEntityOfPage": "https://blog.intheswim.com/hayward-pool-heater-troubleshooting/",
I Have an electric Hayward pool heater that comes on automatically when temperatures drop and then runs 3 or 4 hours. Just opened my in ground pool went to turn the pump on and nothing. my hayward pump will only work when the nob is turned to 110 Aquarite is not powering up at all. You can check power in, on the incoming wires, and power out (with timer ON), on the outgoing wires that go to the motor. I have an older Hayward Pool pump for an above ground pool. Thanks for the schema!! Be sure that bare wires are not touching other bare wires or terminals, or other metals. Try adding another inch of water. Entire pump system with pump basket and housing. near the end of last season it started loosing its prime on and off. I do not think its the breakerits relatively new. A leaking shaft seal should not cause your filter pressure to decrease. Where can I get a new yellow wire to connect the motor to the switch and see if this solves my issue? Hi William, the on/off switch is sold as an entire end-cap piece, including the rear cover, the yellow wire would not be a part that is sold, I suppose you could make it yourself ? It is being practiced by thousands of pool owners just like you. Ive checked out your blog and you had very good info for audience. Another piece of information is that the board was replaced back around May of this year as well as the flow sensor. thank you Kelly. Have no power at all going to my control panel. If so, you may try to glue them in place with JB Weld or similar, and if that doesnt work, a new housing would be in order. The pump then ran fine for about 10 minutes and then stopped working again. I have an sp3400vsp pump. Its a little over 3 years old and the cell checked out fine. Thanks, Jim, if the motor is reversible it will have a Hi Voltage / Lo Voltage diagram printed on the label, and a means to switch it to 115V. The control is set for the wrong turbo cell type. Just disconnect wires, and replace. Great site. What should I check? I even tried another new housing gasket and it still leaks. We have a Hayward Swimpro Lx 1.0 hp and have a slow leak coming from underneath, maybe in between the housing and the motor. Hooked it up the same as the last motor and left the setting to 230 as that is what the last motor was set to run on. For the pool winterization, the usual practice is to remove the filter and drain plugs, and then use rubber expansion plugs, or threaded plastic plugs, to close up the pool skimmer line and the pool wall return lines (where water returns to the pool), after the pipes are drained of water. Hi Craig, could be a clogged filter, needing a flush out and perhaps a filter soak in DE Filter Cleaner. If the meter reads zero, and stays at zero the capacitor is bad. "dateModified": "2/24/2015",
4. leaky valve or unions in front of pump Or is it coincidence that I have a bad line in the pool. Im really uncertain exactly how to even look for a solution to my problem. Attached please find a copy of the Aqua Plus Operation Manual Please note Section - Configuration Menu Items, Cell Type Selection, page 16. of and in " a to was is ) ( for as on by he with 's that at from his it an were are which this also be has or : had first one their its new after but who not they have We would like to show you a description here but the site wont allow us. IF that all looks good, consider replacing the capacitor. Question my Aquaririte is 3 years old. GFCI breakers can go bad, but then again, they can be good, and this symptom could be warning you of a potentially unsafe situation. Also check that the stationary switch (6 oclock) and the centrifugal switch (dead center) are not loose or misaligned. Does anyone know how to reset an sf error code after a new thermistor has been installed? presto, all working good! Hi Tony, there could be a short in the motor, or loose wires connecting to the capacitor, or if the capacitor you are replacing with is not the correct capacitor, or if the centrifugal or stationary switches are not releasing the capacitor, due to loose or misaligned switches, or loose wires, or wires shorting out by touching other wires or the motor casing, or crimped wires give a good look around the back of the motor, and try another capacitor, maybe call Hayward and ask for the correct capacitor MFD number for your horsepower of Northstar. If i knew what make/model of pump you have, I could be more specific. Hi, motors run about 140 F when running, so they are always hot to the touch. Products, learn Check that there is no additional valve to open on the backwash line, and if a flexible backwash hose is used, that it is rolled out. Thinking of switching to PentAir, I hear they are better built. Got pump from a friend and he had no problems. Hi Deb, SF (Sensor Failure) indicates that the temperature sensor (thermistor) is not getting good data to the circuit board. Both the pump motor and Polaris are wired out of the timer and the timer seems to be working correctly and I checked it by checking the voltage at the motor with the switch in the off position and then again with the switch in the on position. I next realized the shaft (impellers) was frozen, and was able to free it up so it now spins smoothly. Air problems dont usually cause the same loud noise, just the low basket water. Ohms reading should be between 0.5 and 1.0 ohms max. I would test the voltage at the motor terminal board, very quickly, before the breaker trips, to be sure its between 210V-250V coming in. Do I need to clean filter? Its a good piece of troubleshooting. Automatic restart is 2 minutes after the error condition is corrected and the limit string closes. The water does not flow when the pump is turned on. I have a new fiberglass pool and ever since I operate it the pump trips the breaker in most cases overnight hours between 2 timing sessions (pump not running). Mark. Is there a resource I can look at to help understand the enter system, that is control by the Aqua Logic Power Panel. Is this normal operation or should I look into replacing the strainer cover o ring? Is this a 2-speed pump, or variable speed pump? In particular, if the salt content of your pool water is too high, your metal screws, handrails, ladders, and covers will rust excessively. I used no lube on the gasket. However this is not correct operation. Perflex filters can also leak out of the bump handle, this fix usually involves replacing the shaft o-rings. Just replaced my old Polaris booster pump, 3/4 hp, with a 1hp pump. Shut down the power to the pump from the breaker for 15 minutes turn back on and try to run the pump. Put everything back in place, turned pool on. You can either take the motor to an electric motor repair shop for rebuilding (new seals/bearings), or buy a new motor, or buy a new pump. Breville Tamper Coffee Kit 54mm, On page 30 of the Aquarite troubleshooting guide, it goes into depth about troubleshooting that rectifier. Camfrog Pro Extreme Atau Gold - Camfrog Indonesia. goes on first, then the spring, then the slightly larger hole washer. Not usually related to a tripped GFI, but I suppose they could be linked. IF the motor is turning over or starting, but no water pumps, it is usually an air leak from a loose pipe coming into the pump, or a loose pump lid. And water around the base. Shock the pool first and overfilter, before pulling pump. What does your water temp say? that would be rare, very rare. Went out today to find the lower plastic shroud melting again? Bob. It can continue to run at that point but its almost like its running at 25% power or even less so we just turned it off. But after that, you should be able to override any programs with the buttons. Anything else to fiddle with or bad motor? Essentially, its probably something loose/broken, or a bad capacitor, which is like the battery to help it get up to high speed. I reset everything when I noticed the problem. When the pressure rises 7-9 psi above the clean, start-up pressure, that indicates that its time to backwash or clean the filter. Weve not had this issue the past 2 years (we bought the house 2 years ago). Then we hear a click and the whole display goes blank. "
Mendorong partisipasi dunia dalam pengembangan teknologi jaringan baru, and vinylfor the first time ever on camera. Hmmm, should work? 5. low water level or skimmer weir blocking water flow Corrosion inside the plug or socket. Sir, I have a Hayward Ecostar 3400 variable speed pump and will not run anymore. There is an internal fan, near the front of the motor, but it is inside and hard to see. Hi Anmarie, Could be the wrong type of sand, but not likely if the bag said Pool Filter Sand on the label. You need to be really sure about the actual salinity reading. But the clicking, that sounds like a centrifugal switch, on the rear of the shaft, which could be a voltage issue? When I turn the switch on for the pool, the breaker flips immediately. Override this by moving the Main Switch to Super Chlorinate. Hello, They are higher voltage or whateverbut could that be the problem? At this point, you can shut off power at the breaker, and pop the mechanism out of the box by depressing the tabs on the top, and inspect the gears and motor directly, for any insect problems, gecko tails (seen it!) The only thing I can think of now is a bad breaker box which is outside adjacent to the pump, it is 20 years old. Tested the switch on and off and it works as expected. Step 1: Wait 60 seconds after the pump starts. that sounds like loose wires, or broken wires. I have an Ecostar That has developed a pinhole spray leak at the top of where the pump housing oring sits between the pump and motor. Select Product to Register: Step 4: Enter the registration information for your product . Impeller replacement is only ever really needed for breakage or other severe damage, so if it aint broke. If your cell looks like 4B, follow the instructions below for cleaning your cell. When it gets up to speed, the switch is supposed to release the capacitor. Only thing I can think of, is the Key assy aligned properly when it was screwed back onto the valve body? Turned it off and then tried it again and it hummed for a few and the something glowed red and then stopped humming. In my experience, a motor overheating is usually on its last legs what you could do is take it to an electric motor shop in town, and have them run it thru some diagnostics, should not be too expensive, but call first to check. For multiport valves, the Spider Gasket inside can become worn, torn or twisted. In the last couple weeks it started getting louder at various times throughout the day. Thanks? This occurred after a lengthy power outage. Ob, and its just over 4 yrs old. The components of a Hayward pool heater are also similar to gas heaters made by other manufacturers. Does the panel just need to dry or did I cause possible damage? It is a Hayward Super Pump 1.5 HP (model #SP2610X15). For the filter, its a common problem, but its usually solved with soaking the fingers in a DE filter cleaner solution, or acid. I checked the power to the timer and I have 120 v to L1 & L2 but timer not running & pump wont run when I turn pump on manually. If no power there, check the timer, if no power there, check the breaker, if no power there Is the main breaker in the house on? Touch both leads of your meter to the capacitor terminals, does not matter which lead touches which terminal. In most cases, its going to be #1, just a frozen motor as we say If the shaft spins freely, and it makes a hum or buzz sound for a few seconds before it trips the breaker, probably #4. BUT THE BEARINGS. Though it is a different control, they use the same cell; so if you are getting a temperature reading of 215, you need to replace the cell. Hi Matt, sound like the bearings have gone bad, and now they are so bad that the shaft has locked up or is binding, and that trips the breaker. We are headquartered in Valley Stream, New York, just outside of New Posted: (10 days ago) Posted: (5 days ago) Mountainside Fitness is located at 9375 E Bell Rd, Scottsdale, AZ 85260.Mountainside Fitness can be contacted at (480) 502-2096. dr myers ultrasound. Hi BRian, nothing special no make sure the outlet TEST button is not popped or tripped? I never had this problem before. Check that the motor wiring matches input voltage, if the motor can be wired 110/220V. Same thing if I try to backwash. The wire size may depend on the distance of wire run. Possibly an obstruction on the return line, after the filter? No lights are coming on as if no power. Could be the use of a clarifier or flocculent that is clogging the sand? Please help! Is this enough to cause it not to prime or is there an issue with the impeller? (I just bought the house and am new to pool upkeep.). Is this just a problem with the thermostat button do you think? Before you test your capacitor, take note of its appearance. Hi COnnie, great question! Hi Michael, that could be a bad or weak capacitor, or a loose wire to the pump motor or to the outlet, or a bad power cord. Hi Davy, Vacuum hose air leaks from splits in an old hose. Motor may still be good. Higher horsepower motors are usually only 230V, above 2 hp, but lower hp motors are sometimes reversible, or have the ability to wire either with 110V or 220V, but they will say this on the motor label if they are (reversible) and have a diagram also. When the problem is after the pump impeller, like a clogged filter, closed return valve or clogged return line, the pressure will be higher than normal. If from the top, try tightening the lid with a #3 Philips, or replace the lid o-ring. APPLY FILTER Pumps Filters Heaters Cleaners Sanitization Automation Lighting White Goods Accessories Solar Safety HI Alberto, if a motor is overheating, it normally takes about 15-20 minutes, and then the thermal overload switch, located in the rear of the motor, will trip, shutting off the pump for about 15-20 minutes, until it is cool enough to start again, on its own. I figure bearing, I pulled the motor off the housing and cleaned a few pine needles out of impeller but nothing else.Its only 2 years old,I take really good care of the equipment so Im surprised. So if the water flow thru the unit is normal then I would next assume a bad flow switch or sensor (depending on what type of pool equipment we are talking about pump, salt cell, heater). How can I secure the top to the filter so the water will not pour out of it while the pump is on filter mode? I have a Hayward H250 pool heater with a digital display. Any suggestions or ideas as to why it is not producing chorine in regular mode? When we turn on power, the pump does not make noise but the timer box and the circuit box make a light humming noise and then the circuit tripped. With the information explained in this comprehensive troubleshooting guide, you can diagnose and repair your Hayward single speed or variable speed pool pump with ease! stabilize. First inspect wiring, to be sure everything is tight and secure, and there are no loose wires, or anything that looks wrong back there. Please remove additional products. . Have a Hayward variable that was replaced last year. Had it running today at high rpm and totally turned off after about 20 minutes. Also, make sure you plug in the cell all the way. What do I need to replace the seal plate, the diffuser, the pump housing? If any of these readings are outside limits, replace motor. New motors are always set to accept 230V when shipped, but can fall out of adjustment, or if you are using 115V, then the motor (if reversible voltage motor), the motor can be switched to accept 115V. Hi David, that would be my first guess, assuming that the power leads are tight, and connections or switches arent loose in the back. How did it end up? Be sure all lines are open, and again check for air leaks. I just replaced my pool pump motor because it was really loud and i figured it was the bearings. Hi Rick, if thats a new thing, there is probably something loose and leaking (air) when the pump shuts off. The Hayward Aqua Plus Automation System should have the capability to accommodate several T-Cell sizes. Repair or replace any tripped breakers or blown fuses. We knows its not electrical. Hayward websites have been developed in compliance with standards for Internet Explorer 10 or later. Hi Stephen, could be a loose wire, not just the power wires, but other wires inside the back perhaps, or loose wires on the timeclock or breaker. If the motor shaft and impeller is spinning freely (not clogged or bound-up), then remove the rear cover to the motor. If your previous pump was also 230V, as it likely was Im not sure what could be the problem, probably not a bad pump, but maybe some wire is disconnected, from the terminal board to the capacitor, for example, or otherwise mis-wired, internally perhaps? Hi Jim, sounds like an air leak, or low water in the pool, or a stuck skimmer weir blocking water flow into the skimmer. If the pump runs without water for very long it will burn up the shaft seal, and if run for hours and days, can literally melt the pump, sometimes even catch fire (rarely), even with a small amount of water in it. I would also suspect the outlet or breaker, but you have tried a different one with the same result. However, I havent tried to spin the shaft. "As for cleaning the pool filters, I do this every couple of days and doesn't help pressure.". Remove the cover plate, and use an insulated screwdriver to discharge the capacitor. Any suggestions what it could be. 2 year warranty. We have just replaced the seal assembly as suggested by a Hayward rep already. 58 amps! I have a humming noise when plugged in, but can seem to get the cover off. I also noticed that the repaired motor Since the flow seems correct, could it be blockage elsewhere? training events, warranty Just opening pool. this is the black cylinder in the rear, at 9 oclock. so.it shut off again. Just bought a brand-new Hayward pump , starts up in primes great but in about five minutes there was no suction or water flow back to the pool . Otherwise, it can be loose or corroded connections on the 3 wires that connect the motor to the drive. Thanks in advance! of and in " a to was is ) ( for as on by he with 's that at from his it an were are which this also be has or : had first one their its new after but who not they have LibriVox is a hope, an experiment, and a question: can the net harness a bunch of volunteers to help bring books in the Dec 14, 2021. In some instances, it could just be a bad breaker. (GFI 240V 20amp) I noticed the on/off switch seemed loose and when I took of the end case, the male disconnect to the switch was burned out. Calling the pool builder for warranty info, too. If your motor is overheating, and shutting off (from the thermal overload switch, located in the back, at 12 oclock), then you have some motor issues, maybe blocked air vents, broken internal fan, or a short across the windings.